Table
3-4. ANL-W site environmental
surveillance program summary (2002). |
|||
|
Medium Sampled |
Type of
Analysis |
Frequency |
Minimum
Detectable Concentration |
|
Airborne
Effluents |
Nitrogen oxides |
Continuous |
NAa |
|
Airborne
Effluents |
Sulfur dioxide |
Continuous |
NA |
|
Soil |
Specific gamma |
7 annually |
0.7 pCi/g |
|
|
Pu, Th, U isotopes |
7 annually |
0.005 pCi/g |
|
|
|
|
|
|
|
Metals |
1 annually |
Varies by analyte |
|
Vegetation |
Specific gamma |
8 annually |
0.7 μCi/g |
|
|
Pu, Th, U isotopes |
8 annually |
0.005 μCi/g |
|
Drinking
Water |
Gross alpha |
1 quarterly |
3 pCi/L |
|
|
Gross beta |
1 quarterly |
2 pCi/L |
|
|
Tritium |
1 quarterly |
400 pCi/L |
|
|
Inorganics |
1 every 9 years |
Varies by analyte |
|
|
Lead/copper |
20 triennially |
1.94 μg/L/6 μg/L |
|
|
Nitrate |
1 annually |
0.1 mg/L |
|
|
Cyanide |
1 triennially |
10 μg/L |
|
|
Arsenic |
1 triennially |
1.7 μg/L |
|
|
Coliform bacteria |
1 quarterly |
NA |
|
|
Volatile organics |
1 every six years |
Varies by analyte |
|
|
Semivolatile organics |
1 every six years |
Varies by analyte |
|
Surface
Water |
Inorganics |
1 annually |
Varies by analyte |
|
|
Anions |
2 annually |
Varies by analyte |
|
|
Gross Alpha |
3 monthly |
3 pCi/L |
|
|
Gross Beta |
3 monthly |
2 pCi/L |
|
|
Gamma Spec |
3 monthly |
Varies by analyte |
|
|
Tritium |
3 monthly |
400 pCi/L |
|
|
Water Quality Parametersb |
3 monthly |
Varies by analyte |
|
Groundwater |
Inorganics |
5 semiannually |
Varies by analyte |
|
|
Anions (Cl, SO4, NO3) |
5 semiannually |
Varies by analyte |
|
|
TOCc |
5 semiannually |
260 μg/L |
|
|
TOXc |
5 semiannually |
2.4 μg/L |
|
|
Gross Alpha |
5 semiannually |
3 pCi/L |
|
|
Gross Beta |
5 semiannually |
2 pCi/L |
|
|
Uranium isotopes |
5 semiannually |
Varies by analyte |
|
|
Tritium |
5 semiannually |
400 pCi/L |
|
|
Water Quality Parametersd |
5 semiannually |
Varies by analyte |
|
Direct Radiation Exposure (HPICs)e |
Ionizing radiation |
4 Continuous |
10 μR |
|
Direct Radiation
Exposure (portable
radiation survey) |
Gamma radiation |
1 annually |
NA |
|
a. NA = not applicable. This information is recorded as an
instrument reading at the time of inspection. b. Surface water quality parameters include
pH, temperature, specific conductivity, dissolved oxygen, and turbidity/
total dissolved solids. c. TOC = Total Organic Carbon; TOX = Total
Organic Halogens. d. Groundwater quality parameters include
pH, total alkalinity, bicarbonate alkalinity, carbonate alkalinity, total
dissolved solids, and specific conductivity. e. HPIC = High Pressure
Ionization Chamber. |
|||