Table 3-4.  ANL-W site environmental surveillance program summary (2002).

Medium Sampled

Type of Analysis

Frequency

Minimum Detectable Concentration

Airborne Effluents

Nitrogen oxides

Continuous

NAa

Airborne Effluents

Sulfur dioxide

Continuous

NA

Soil

Specific gamma

7 annually

0.7 pCi/g

 

Pu, Th, U isotopes

7 annually

0.005 pCi/g

 

 

 

 

 

Metals

1 annually

Varies by analyte

Vegetation

Specific gamma

8 annually

0.7 μCi/g

 

Pu, Th, U isotopes

8 annually

0.005 μCi/g

Drinking Water

Gross alpha

1 quarterly

3 pCi/L

 

Gross beta

1 quarterly

2 pCi/L

 

Tritium

1 quarterly

400 pCi/L

 

Inorganics

1 every 9 years

Varies by analyte

 

Lead/copper

20 triennially

1.94 μg/L/6 μg/L

 

Nitrate

1 annually

0.1 mg/L

 

Cyanide

1 triennially

10 μg/L

 

Arsenic

1 triennially

1.7 μg/L

 

Coliform bacteria

1 quarterly

NA

 

Volatile organics

1 every six years

Varies by analyte

 

Semivolatile organics

1  every six years

Varies by analyte

Surface Water

Inorganics

1 annually

Varies by analyte

 

Anions

2 annually

Varies by analyte

 

Gross Alpha

3 monthly

3 pCi/L

 

Gross Beta

3 monthly

2 pCi/L

 

Gamma Spec

3 monthly

Varies by analyte

 

Tritium

3 monthly

400 pCi/L

 

Water Quality Parametersb

3 monthly

Varies by analyte

Groundwater

Inorganics

5 semiannually

Varies by analyte

 

Anions (Cl, SO4, NO3)

5 semiannually

Varies by analyte

 

TOCc

5 semiannually

260 μg/L

 

TOXc

5 semiannually

2.4 μg/L

 

Gross Alpha

5 semiannually

3 pCi/L

 

Gross Beta

5 semiannually

2 pCi/L

 

Uranium isotopes

5 semiannually

Varies by analyte

 

Tritium

5 semiannually

400 pCi/L

 

Water Quality Parametersd

5 semiannually

Varies by analyte

Direct Radiation Exposure (HPICs)e

Ionizing radiation

4 Continuous

10 μR

Direct Radiation Exposure

(portable radiation survey)

Gamma radiation

1 annually

NA

a.     NA = not applicable.  This information is recorded as an instrument reading at the time of inspection.

b.     Surface water quality parameters include pH, temperature, specific conductivity, dissolved oxygen, and turbidity/ total dissolved solids.

c.     TOC = Total Organic Carbon; TOX = Total Organic Halogens.

d.     Groundwater quality parameters include pH, total alkalinity, bicarbonate alkalinity, carbonate alkalinity, total dissolved solids, and specific conductivity.

e.     HPIC = High Pressure Ionization Chamber.